Table of contents

Live DSPQueue diagnostic reproduction

Kokoro-Hexagon 0a03be39Updated 2026-09-26

The historical diagnostic echo script was rerun through the installed AndroidSMA preview app on the attached Razr+ 2024 and S23. This was a diagnostic investigation only, not Kokoro synthesis or a product transport test. The runner backed up and restored each app's startup scripts and prior result byte-for-byte after each attempt.

The first Razr+ attempt created and exported a queue, but could not open its custom DSP skeleton because that artifact was absent from the diagnostic app's private library directory. A byte-identical copy of the S23 diagnostic app's archived skeleton was then staged to the Razr+ diagnostic app and verified by SHA-256. This binary's source is not in the current repository; it was neither inspected nor admitted to the production build. The generated transfer copy is in git-ignored build/diagnostics/. The diagnostic-app copy remains on the Razr+; it was not present before this test.

Gate Razr+ with recovered skeleton S23 with existing skeleton
Unsigned PD, queue create/export Pass Pass
Skeleton open and queue import/start Pass Pass
First queue write Success (script reached read) Success (script reached read)
First response read Error 12 Error 12
Recovery status 0 packets received; DSP error 14 0 packets received; DSP error 14
Startup scripts and prior result restored Yes Yes

The pinned Qualcomm error definitions name 12 AEE_EEXPIRED and 14 AEE_EBADPARM. Its CPU queue reader passes a read timeout to wait_signal_locked, which maps expiration to 12. That explains the host-side read result but does not identify why the custom worker reports 14.

The two archived echo scripts differ overall, but their queue creation, worker start, and first 32-packet echo-loop source blocks are byte-identical. Their older stored results passed, so the current failure is a regression relative to those records, not proof that either chipset lacks the queue. The reported ~0.1 ms round trip was not reproduced with the archived binary: no packet completed in that phase, so it produced no latency sample.

Do not infer the worker error's cause from Antigravity's candidate kernel sources: the installed kernels do not match those revisions, and both phones reach the same application-level worker failure.

Source recovery and source-matched rerun

A one-time, read-only inspection of the exact diagnostic source and build script in the separate Antigravity checkout located the authored worker at src/kernels/queue-echo/echo.c and its build script at tools/Build-DspQueueEchoProbe.ps1, commit 85b20cc80570c20c53d2ca1c43dc03a66aae08ae. Both files match that commit. The pinned SDK 6.4.0.2 build script verified its tool and header digests and emitted a fresh diagnostic worker into this repository's ignored build/diagnostics/; it made no changes to the Antigravity checkout. The new library has the same byte length as, but a different digest from, the archived installed library. Binary contents were not inspected.

The diagnostic source and a build script adapted to this repository's git-ignored build/ are now retained at tools/reference/dspqueue-echo/. The C translation unit is isolated reference material, not a production implementation. Its executable body matches the recorded source, and the local pinned build completed with the expected library byte length. That repository-local build was then run on both phones with the same guarded staging and restoration procedure: Razr+ warm queue median 124.531 µs versus 226.041 µs synchronous; S23 warm queue median 282.812 µs versus 341.042 µs synchronous. Both runs passed, reported 64 DSP packets received with zero worker errors, and restored the prior worker and diagnostic-app state. The detailed table below records the preceding build from the same executable source body.

The source shows that status error 14 can come from the callback error argument before any packet is received. It does not establish why the archived binary took that path. Replacing the worker temporarily with the fresh source-built artifact, while retaining and then restoring the original worker on each phone, produced these same-session results:

Source-built worker Razr+ 2024 S23
Queue packets completed 32 32
Warm queue round-trip median 120.364 µs 283.907 µs
Warm queue round-trip p95 163.177 µs 354.948 µs
Warm queue write median 56.823 µs 12.969 µs
Warm queue read median 62.708 µs 270.990 µs
Poll-mode warm median 152.135 µs 249.062 µs
Poll read attempts median 1 24
Synchronous-invoke warm median 230.000 µs 347.709 µs
DSP received / error 64 / 0 64 / 0
Diagnostic passed Yes Yes
Prior worker and app state restored Yes Yes

This reproduces an approximately 0.1 ms diagnostic queue round trip on the Razr+ (measured 0.120 ms in this run), not a 0.100 ms exact figure or Kokoro speech. The identical freshly built worker completes on both devices. The S23 response-read interval is much longer, but the result alone does not identify whether DSP execution, queue signaling, scheduler behavior, or another factor accounts for it. No per-packet explicit FastRPC invoke occurs in the PowerShell packet loop; library-internal signaling remains unmeasured.